【Related Standards】 EC / DIN EN 60601-1: Medical electrical equipment – General requirements for safety IEC 60364-7-710: Electrical installations of buildings – Requirements for special installations or locations – Medical facilities DIN EN 793 (VDE 0750 Part 211): Specific requirements for the safety of medical supply units DIN 42801: Connection bolts for equipotential bonding conductors DIN 42801 Part 2: Equipotential bonding conductors, connection sockets Medical Standards: (USA: AAMI ES 60601-1 Canada: CSA C22.2 No. 60601-1 and in EU countries: EN 60601-1) | 【Case Studies】 ■ Micro motor for dental treatment devices ■ Operating room lighting ■ Connector for EEG (electroencephalogram) ear clip electrodes ■ Connector for ECG (electrocardiogram) connection cables ■ Electrosurgery foot switch ■ Electrosurgery hand pencil ■ Surgical devices ■ Equipotential bonding for various medical devices ■ CT scan device power supply ■ Connection for mobile devices ■ Medical ergometer ■ Blood analysis equipment ■ Medical hair removal device ■ Medical printer ■ Medical monitor ■ Electrical low-frequency stimulation device (stimulator) ■ Rehabilitation equipment ■ Dialysis equipment ■ Endoscope ■ Dental chair | ||
【Other Features】 ■ A wide range of product lineup available, selectable from power, signal, data communication, thermocouples, coaxial, optical fiber, non-drip water cooling, and compressed air. ■ Options for manual and automatic connection and disconnection methods. *For more details, please refer to the PDF materials or feel free to contact us. | For more details, please refer to the PDF document or feel free to contact us. | ||
Contact System: MULTILAM Rated Voltage: Maximum 830 V Rated Current: Maximum 200 A Overvoltage Category: CATIII Test Voltage: 0.84 kV – 3.31 kV / 50 – 60 Hz / 1 minute Insulation Coordination: Compliant with IEC 60664-1, DIN VDE 0110-1 4 kV: 3 V – 300 V 6 kV: 3 V – 630 V | ●Testing systems ●Machine tools ●Coating systems ●Automobiles (press factories and body assembly plants) ●Fixture holding devices ●For other applications and more details, please contact us or download the catalog. | ||
---
--- |
--- |
-
- Featured Products
-
Medical device connector - Medical technology
- overview
- 【Related Standards】 EC / DIN EN 60601-1: Medical electrical equipment – General requirements for safety IEC 60364-7-710: Electrical installations of buildings – Requirements for special installations or locations – Medical facilities DIN EN 793 (VDE 0750 Part 211): Specific requirements for the safety of medical supply units DIN 42801: Connection bolts for equipotential bonding conductors DIN 42801 Part 2: Equipotential bonding conductors, connection sockets Medical Standards: (USA: AAMI ES 60601-1 Canada: CSA C22.2 No. 60601-1 and in EU countries: EN 60601-1)
- Application/Performance example
- 【Case Studies】 ■ Micro motor for dental treatment devices ■ Operating room lighting ■ Connector for EEG (electroencephalogram) ear clip electrodes ■ Connector for ECG (electrocardiogram) connection cables ■ Electrosurgery foot switch ■ Electrosurgery hand pencil ■ Surgical devices ■ Equipotential bonding for various medical devices ■ CT scan device power supply ■ Connection for mobile devices ■ Medical ergometer ■ Blood analysis equipment ■ Medical hair removal device ■ Medical printer ■ Medical monitor ■ Electrical low-frequency stimulation device (stimulator) ■ Rehabilitation equipment ■ Dialysis equipment ■ Endoscope ■ Dental chair
Automation of processes such as inspection using automatic connection connectors [Case study collection available].
- overview
- 【Other Features】 ■ A wide range of product lineup available, selectable from power, signal, data communication, thermocouples, coaxial, optical fiber, non-drip water cooling, and compressed air. ■ Options for manual and automatic connection and disconnection methods. *For more details, please refer to the PDF materials or feel free to contact us.
- Application/Performance example
- For more details, please refer to the PDF document or feel free to contact us.
High durability, high voltage, high current - detachable up to 1 million times【Electrical Connector】
- overview
- Contact System: MULTILAM Rated Voltage: Maximum 830 V Rated Current: Maximum 200 A Overvoltage Category: CATIII Test Voltage: 0.84 kV – 3.31 kV / 50 – 60 Hz / 1 minute Insulation Coordination: Compliant with IEC 60664-1, DIN VDE 0110-1 4 kV: 3 V – 300 V 6 kV: 3 V – 630 V
- Application/Performance example
- ●Testing systems ●Machine tools ●Coating systems ●Automobiles (press factories and body assembly plants) ●Fixture holding devices ●For other applications and more details, please contact us or download the catalog.
-